TRION(3) Power Modules
Simultaneous sampling for all analog inputs
Discover our TRION(3) series high-speed power modules, ideal for precise 4-phase power analysis. Benefit from user-exchangeable signal conditioning modules that provide separate A/D conversion on each channel up to 10 MS/s and additional sub-modules for unmatched flexibility in meeting your power analysis requirements.
POWER MODULES
Discover TRION(3) series high-speed power modules, ideal for precise 4-phase power analysis. Benefit from user-exchangeable modules and additional sub-modules for unmatched flexibility in meeting your power analysis requirements.
CHANNELS | SAMPLE RATE/CH. | RESOLUTION | ISOLATION | CONNECTOR TYPES | |||
TRION3-1810M-POWER
|
![]() ![]() |
Datasheet | 8 (4 U / 4 I) | 10 MS/s | 18-bit | ISO | Fixed: 4 x Safety banana, CAT III 1000 V – Exchangeable: 4 x sub-modules |
TRION3-1820-POWER
|
![]() ![]() |
Datasheet | 8 (4 U / 4 I) | 2 MS/s | 18-bit | ISO | Fixed: 4 x Safety banana, CAT III 1000 V – Exchangeable: 4 x sub-modules |
TRION-1820-POWER
|
![]() ![]() |
Datasheet | 8 (4 U / 4 I) | 2 MS/s | 24-bit | ISO | Fixed: 4 x Safety banana, CAT III 1000 V – Exchangeable: 4 x sub-modules |
TRION-1810-HV
|
![]() |
Datasheet | 8 (4 U / 4 I) | 1 MS/s | 24-bit | ISO | Fixed: 4 x Safety banana, CAT III 1000 V – Exchangeable: 4 x sub-modules |
TRION3-1810-SUB-8
|
![]() ![]() |
Datasheet | 8 | 1 MS/s | 18-bit | ISO | Fixed: 0 – Exchangeable: 8 x sub-modules |
Compatibility: The high-speed DEWE3 systems support both, TRION3 and TRION modules. The DEWE2 systems only support TRION modules.
Here you find the overview of our DAQ systems.
USER- EXCHANGEABLE SUB-MODULES
In combination with our power modules (see the table above), the interchangeable TRION(3) sub-modules can be used to create individual input configurations. Because of the unique modularity, up to 8 channels can be equipped with different sub-modules for direct current or voltage measurement. Thus almost any kind of voltage or current sensor can be connected to a DEWETRON power analyzer. The sub-modules are user-exchangeable at any time, automatically detected and the calibration data is directly stored inside the sub-module.
SUB-MODULES FOR CURRENT INPUT (directly & sensors)
RANGE | SAFETY | BANDWIDTH | CONNECTOR | EXCHANGEABLE BY USER | |||
Current transducer module TRION-SUB-CT |
![]() |
Datasheet | 1 ARMS (±2 APEAK) 0.5 ARMS (±1 APEAK) 0.25 ARMS (±0.5 APEAK) 0.1 ARMS (±0.2 APEAK) |
Not isolated. Depending on connected current clamp |
5 MHz | D-SUB-9 socket | Yes |
20 A module TRION-POWER-SUB-CUR-20A |
![]() |
Datasheet | 20 ARMS (±40 APEAK) |
CAT II 600 V, unfused | 300 kHz | Safety banana (male) | Yes |
2 A module TRION-POWER-SUB-CUR-2A |
![]() |
Datasheet | 2 ARMS (±4 APEAK) |
CAT II 600 V, unfused | 300 kHz | Safety banana (male) | Yes |
1 A module TRION-POWER-SUB-CUR-1A |
![]() |
Datasheet | 1 ARMS (±2 APEAK) |
CAT II 600 V, unfused | 300 kHz | Safety banana (male) | Yes |
0.2 A module TRION-POWER-SUB-CUR-02A |
![]() |
Datasheet | 0.2 ARMS (±0.4 APEAK) |
CAT II 600 V, unfused | 300 kHz | Safety banana (male) | Yes |
SUB-MODULES FOR VOLTAGE INPUT
RANGE | SAFETY | BANDWIDTH | CONNECTOR | EXCHANGEABLE BY USER | |||
1 V module TRION-POWER-SUB-dLV-1V |
![]() |
Datasheet | 1 VRMS (±2 VPEAK) |
Not isolated. Depending on connected current clamp |
5 MHz | D-SUB-9 socket | Yes |
5 V module TRION-POWER-SUB-dLV-5V |
![]() |
Datasheet | 5 VRMS (±10 VPEAK) |
Not isolated. Depending on connected current clamp |
5 MHz | D-SUB-9 socket | Yes |
Clamp input module TRION-POWER-SUB-dLV-1 |
![]() |
Datasheet | 5 VRMS (±10 VPEAK) |
Not isolated. Depending on connected current clamp |
150 kHz | D-SUB-9 socket | Yes |
600 V module TRION-SUB-600V |
![]() |
Datasheet | 600 VRMS (±1500 VPEAK) |
CAT II 600 V, isolated | 300 kHz | Safety banana | Yes |
5 V module TRION-SUB-5V |
![]() |
Datasheet | 5 VRMS (±10 VPEAK) |
CAT II 600 V, isolated | 300 kHz | Safety banana | Yes |
Seamless auto-range module TRION-SUB-XV |
![]() |
Datasheet | 600 VRMS (±850 VPEAK) 60 VRMS (±100 VPEAK) 6 VRMS (±10 VPEAK) 0.6 VRMS (±1 VPEAK) |
CAT II 600 V, isolated | 300 kHz | Safety banana | Yes |
Fixed High-Voltage Inputs
4 channels on each power module are fixed high-voltage inputs with ±2000 VPEAK. The other 4 channels are free for different user-exchangeable sub-modules. The only exception is the TRION3-1810-SUB-8 modul:
With its 8 user-exchangeable sub-modules, it is the most flexible TRION power module.

RANGE | SAFETY | BANDWIDTH | CONNECTOR | ||
Voltage Input U1, U2, U3, U4 |
![]() |
1000 V (±2000 VPEAK) |
CAT IV 600 V / CAT III 1000 V |
5 MHz | Safety banana |